Sara L. Jackson

Sara L. Jackson

Sara L. Jackson, at the University of Washington, is first and corresponding author of the clearest measurement of noise in professional judgement that medicine has produced. Forty-nine pathologists interpreted the same sixty breast specimens twice, at least nine months apart, producing 2,940 interpretations. On the difficult call of atypia, the same pathologist agreed with his own earlier reading 53 per cent of the time; a different pathologist agreed 43 per cent of the time.

Who they are

Jackson is a physician-researcher at the University of Washington. Credit for this study belongs to her: she is first and corresponding author, and Joann G. Elmore, whose name is more often attached to it, is last author.

The design is the contribution, and it is what makes the figures interpretable. Pathologists across eight American states interpreted sixty breast specimens, one glass slide per case, on two occasions separated by at least nine months. Forty-nine completed both phases. The separation matters because re-presenting a case within a session measures memory rather than stability, and the authors of Noise make the same point about the published literature on this question.

The figures. Same pathologist, nine months apart: invasive breast cancer 92 per cent, ductal carcinoma in situ 84, atypia 53, benign without atypia 84. Different pathologists on the same material: 89, 79, 43 and 77.

Her own conclusion is the sentence an entire argument turns on, that agreement between a pathologist and their own earlier reading of the same slide, for atypia, was about as low as the agreement seen between different pathologists.

Ten percentage points on the hard call. That is the measured value of your own earlier mind, and it is the sharpest available answer to whether a second opinion should come from the same person or somebody else.

And the figure that generalises further: the spread is a property of the diagnostic category rather than of the profession. Ninety-two per cent and fifty-three per cent came from the same forty-nine pathologists reading the same sixty slides.

Nothing on this page is clinical advice. The study measured agreement rather than accuracy, and it did not follow any outcome for a patient.

Key papers

No book has been verified for this page and none is listed.

Jackson, S. L., Frederick, P. D., Pepe, M. S., Nelson, H. D., Weaver, D. L., Allison, K. H., Carney, P. A., Geller, B. M., Tosteson, A. N. A., Onega, T., & Elmore, J. G. (2017), Diagnostic Reproducibility: What Happens When the Same Pathologist Interprets the Same Breast Biopsy Specimen at Two Points in Time?, Annals of Surgical Oncology 24(5), 1234-1241, doi:10.1245/s10434-016-5695-0. Abstract read in full at the Europe PMC core record; full text not read, subscription required. Author order verified at OpenAlex and cross-confirmed at Europe PMC: Jackson first and corresponding, University of Washington, with Elmore last.

Key ideas

Separate the sittings. Nine months between readings is what distinguishes a measurement of stability from a measurement of recall.

Ten percentage points. The measured gap between a second look by the same expert and a first reading by a different one, on the hard call.

The spread belongs to the question. Ninety-two per cent on invasive cancer and fifty-three on atypia, from the same readers, means a reliability figure quoted without its diagnostic category carries almost no information.

Agreement is not accuracy. Her study reports how often readers filed the same answer, and not how often they were right.


Sources

  1. Jackson, S. L., and colleagues (2017), Annals of Surgical Oncology 24(5), 1234-1241, doi:10.1245/s10434-016-5695-0. Abstract read in full; full text not read.
  2. Elmore, J. G., and colleagues (2017), BMJ 357, j2813, doi:10.1136/bmj.j2813. Full text read, for the melanoma companion measurement. A correction published 8 August 2017 has not been read.
  3. Ridge, C. A., and colleagues (2016), Radiology 278(3), 888-896, doi:10.1148/radiol.2015150714. Abstract and reference list read; body not read.
  4. Noise: A Flaw in Human Judgment, for the test-retest design caveat her design satisfies.

Articles that cite Sara L. Jackson

  • Two Readings of the Same Case

    The subject is variance, not bias, and the strongest measurements of it are medical rather than financial. The insurance figure everyone quotes was published in a practitioner magazine with…

Concepts on this site

  • Inter-Rater Reliability

    Inter-rater reliability is how far two qualified raters agree when they score the same material. It comes in two flavours that get conflated: raw agreement, the share of cases where two readers…

  • Occasion Noise

    Occasion noise is the variability in judgements of the same case by the same person at different times. It is the transient share of pattern noise, the part that would not come back if the same…

  • Second Opinion

    Two different things go under one name. A second look, where the same expert reads the same material again after a delay. And a second opinion, where a different expert reads it. Both reduce system…

  • System Noise

    System noise is unwanted variability in judgements that should ideally be identical. Not error against a known answer, but scatter among equally qualified people looking at the same case. Its best…